Fire Alarm & Safety System

At Panel Technologies, we pride ourselves on delivering top-notch fire alarm and safety systems, ensuring that all client requirements are met with excellence. In today’s world, a reliable fire alarm system is not just a luxury; it’s a necessity. Our fire alarm solutions are designed to provide unparalleled protection against fire hazards, safeguarding both lives and property. When it comes to fire alarm safety, we understand the importance of quality and reliability, making sure our fire alarm systems are equipped to respond swiftly in emergencies.

Click here to read in detail about the importance of Fire alarm & safety systems

Addressable Smoke Detector-NF5161

  • 2-Wire non-polarized signal
  • Infrared scattering technology
  • Simple Electronic Addressing
  • Programmable Sensitivity Level
  • Drift compensation and fault detection function

Specification

Voltage

Loop: DC24V(18.5~26V)

Current

Standby Current:≤0.3mA; Alarm Current:≤0.8mA

IP Rating/Type

IP23/ABS Enclosure/ Milky White

Indicator

Red, Flashes when polling, Illuminates in alarm

Dimension

100mm x 51mm (with base)

Operating Environment

Temperature:-10°C~+55°C, Relative Humidity: ≤95% non-condensing

Addressable Heat Detector- NF5162

  • 2-Wire non-polarized signal
  • Thermal sensitive element improves the
  • response time of temperature variation
  • Rate of Rise & fixed type heat detector
  • Simple Electronic Addressing

Specification

Voltage

Loop: DC24V(18.5~26V)

Current

Standby Current:≤0.3mA; Alarm Current: ≤0.8mA

IP Rating/Type

IP33/ABS Enclosure/ Milky White

Indicator

Red, Flashes when polling, Illuminates in alarm

Dimension

100mm x 50mm (with base)

Operating Environment

Temperature:-10°C~+50°C, Relative Humidity:≤95% non-condensing

Addressable Combined Heat & Smoke Detector-NF5163

  • Combined heat & smoke multi sensor
  • 2-Wire non-polarized signal
  • Temperature and humidity drift compensation,
  • dust accumulation degree indication
  • Simple Electronic Addressing
  • Self-diagnostic function
  • Programmable Sensitivity Level

Specification

Voltage

Loop: DC24V(16~28V)

Current

Standby Current: ≤0.3mA; Alarm Current: ≤0.9mA

IP Rating/Type

IP23/ABS Enclosure/ Milky White

Indicator

Red, Flashes when polling, Illuminates in alarm

Dimension

100mm x 50mm (with base)

Operating Environment

Temperature: -10°C~+55°C, Relative Humidity:≤95% non-condensing

Addressable Sounder Strobe-NF5266

  • 2-wire non-polarized signal
  • 2-wire Non-polarized DC24V power
  • Multilevel filter can effectively suppress
  • the interference signal
  • Simple Electronic Addressing

Specification

Voltage

Loop: DC24V(18.5~26V); Power: DC24V (19V~28V)

Current

Standby Current:≤0.2mA; Power ≤0.5mA

Operating Environment

Temperature: -10°C~+50°C; Relative Humidity: ≤95% (40±2°C)

Active Current

Loop: ≤1.5mA;Power: ≤30mA

Sound Level

80dB 115dB (A weighted)

Dimension

115mmx55.3mmx140mm

Digital Manual CallPoint-NF5264

  • Simple Plug-in structure
  • Convenient installation
  • Alarm by pressing, reset by a special key
  • Simple Electronic Addressing

Specification

Voltage

Loop DC24V (16V~28V)

Current

Standby Current: ≤0.2mA; Alarm Current: ≤0.8mA

Operating Environment

Temperature: -10°C~+55°C; Relative Humidity: ≤95%, non-condensing

Mounting Hole Distance

60mm

Dimension

95mmx44mmx95mm (with base)

Addressable Monitor Module -NF5261

  • 2-Wire non-polarized signal
  • Simple Electronic Addressing
  • Line detecting function for input

Specification

Voltage

Loop: DC24V(16V~28V)

Current

Standby Current:≤0.2mA;Action Current:≤0.8mA

Operating Environment

Temperature: -10°C~+55°C; Relative Humidity: ≤95%, non-condensing

Mounting Hole Distance

60mm

Dimension

86mmx38mmx86mm (with base)

Working Mode

Match with NF5109

Addressable Input - Output 1/0 Control Module - NF5263

  • Active and passive output
  • Line detecting function for input and output
  • Input terminal is set as normal open detecting function connected with passive contract
  • Simple Electronic Addressing

Specification

Voltage

Loop: DC24V (18.5V~26V); Power: DC24V (19V~28V)

Current

Loop: ≤0.2mA;Power: <2mA

Operating Environment

Temperature: -10°C~+55°C; Relative Humidity: ≤95%, non-condensing

Active Current

Loop: ≤2mA;Power: ≤22mA

Mounting Hole Distance

60mm

Dimension

86mmx38mmx86mm (with base)

Working Mode

Match with NF5109

Loop Isolator-NF5260

  • Polarized connection with peripheral devices.
  • Simple Electronic Addressing
  • No need to transfer connection of input and output.

Specification

Voltage

Loop DC24V(18.5-26V)

Current

Standby Current ≤ 5.5mA, Action Current ≤ 25mA

Operating Environment

Temperature: 0°C~+49°C; Relative Humidity: ≤95%, non-condensing

Mounting Hole Distance

60mm

Dimension

95mmx44mmx95mm (with base)

Working With

Match with NF5109

TRANSMISSION DEVICE/REPEATER/TCP/IP MODULE

  • Compact Repeater with Built in LCD Display and Alar Hooter
  • External Antenna for additional signal strength
  • Connects to Internet via wi-fi and LAN/RJ45
  • Works with SIM / GPRS
  • Connects to Fire Alarm Panel via 2 wire – CAN Protocol
  • Connects to up to 31 Panels
  • Uplinks Fire Events and Faults to Smart Fire Platform
  • Enables Remote Monitoring
  • Built in Battery for power failure support

Specification

Voltage Rating

24V DC

Size

254 mm X 50.8 mm X 152.4 mm

Color

White ABS

Standard

IP33

Aspirating Detector- NF5801

    • Robust absolute smoke detection
    • Two Pipe & four pipe model available
    • Intelligent Filter
    • Link trap to capture fibrous particles
    • Selectable Air flow Speed

 

    • Clean air barrier for optics protection
    • Air-path monitoring feature
    • Selectable sensitivity Level
    • Can be connected as fire panel loop device

Independent Combustible Gas Detector- NF521

  • Equipped with high-quality gas sensor
  • The intelligent algorithm of the micro
  • processors can compensate for the drift of gas sensor
  • LEDs indicate the detector status of normal, alarm and fault

Specification

Voltage Rating

AC220V

Current

Standby Current:6mA, Alarm Current:7mA

Alarm Concentration

CH4, 8%LEL

Operating Environment

Temperature: -10°C~+50°C; Relative Humidity: <95%

Sound Level

>75dB

Dimension

120mmx86mmx48mm

Intelligent Combustible Gas Detector- NF518

  • Electronically addressed
  • Monitor natural gas, manufactured gas, liquefy petroleum gas and other combustible gasses
  • Active contact, applying to DC12V Single-phase
  • DC pulse solenoid valve; the drive capability of a solenoid valve:1000gF capacity discharge
  • Able to shutdown the valve
  • Widely used homes, hotels, apartments etc.

Specification

Voltage

Loop: DC24V(18V~28V); Power:DC24V(20V~28V)

Current

Standby Current:21mA, Alarm Current:28mA

Alarm Concentration

CH4,8%LEL

Operating Environment

Temperature: -10°C~+50°C; Relative Humidity: ≤95% >75dB

Sound Level

>75dB

Intelligent Combustible Gas Detector-NF516

  • Electronical coding
  • Ceiling-mounted
  • Electronically addressed
  • Detect natural gas, manufactured gas, liquefied petroleum gas and other combustible gas
  • Active contact, applying to DC12V Single-phase dc pulse solenoid valve; the drive capability of a solenoid valve: 1000gF capacity discharge
  • Widely used in homes, hotels, apartments etc.

Specification

Voltage

Loop: DC24V(16V-28V); Power: DC24V(20V-28V)

Current

Standby Current: loop: ≤1.1 mA, Power: ≤9mA

Operating Environment

Temperature: -10°C~+50°C; Relative Humidity: ≤95%, non-condensing

Sound Level

75db

Independent Photoelectric Smoke Detector- NF901

  • Independent Photoelectric Smoke Detector
  • Power: 6F22 DC9V battery
  • Indicator Red Flashes every 45s when polling
  • Battery life:3-5 years

Specification

Power Supply

6F22 DC9V battery

Current

Standby Current: ≤5uA; Alarm Current: ≤7mA

Operating Environment

Temperature: -10°C~+50°C; Relative Humidity: ≤90%, non-condensing

Dimension

100mm×54mm (with base)

Emergency Lighting System

Centralized monitoring- system

Emergency lights are centralized powered & monitored for better illumination and evacuation of occupants. Our solutions are complied with relevant standards. Available in wall mounted & desktop type panels.

Networkable Panels

Panels can be easy networkable to cater small to large system requirement with CAN communication protocols to go up-to 61440 units effectively.

Cost effectives yet efficient

Our solutions are most cost effective in the market with robust installation and built quality to run for longer life and protection to occupants.

Power savings

Our luminaries consume less power and are fully automated to save on electricity which made it environment friendly too.

NOTOFIRE FIRE SURVIVAL CABLE

  • Circuit Integrity at 9500C for 2 Hours
  • Insulation: XPLE / LSZH with MICA Tape 1050 Degree Rated
  • Round GI Steel Wire Armoured
  • LSZH (Low Smoke Zero Halogen) Outer Jacket

Specification

Type

Fire Survival Cable

Size

2 Core X 1.5 Sq.mm

Color

Red/Black/As per requirement

Standard

BS 7846 and BS 6387

Voltage Rating

300/600 V

NOTOFIRE FIRE RETARDANT "FIRE ALARM CABLE"

  • Temperature Range 300C to + 700C
  • Insulation: XPLE / LSZH
  • Round GI Steel Wire Armoured
  • LSZH (Low Smoke Zero Halogen) Outer Jacket

Specification

Type

Fire Alarm System Arm Cable

Size

1.5 Sq.mm

Color

Red/Black/As per requirement

No. Of Cores

2 Core

Standard

BS 6387